styleUT383

UT383 Mini Lux Meter with 0–200,000 Lux Measurement Range

UT383 mini digital lux meter with backlight, 0–200,000 lux range and 163 × 55 mm body

The UT383 mini lux meter is a digital illuminance meter for checking and recording light levels. Its stated measuring range extends from 0 to 200,000 lux, while the foot-candle range covers 0 to 9,999 Fc in 1 Fc increments. Readings are sampled every 0.5 seconds, and an OL indication identifies an overload. MAX/MIN measurement, data HOLD and a display backlight provide several ways to review measurements without adding unrelated functions. Measuring 163 × 55 mm, the meter has a compact stated footprint. It operates from a 4.5V battery supply, shuts down automatically after five minutes and gives a low-battery prompt at approximately 3.0–3.5V. The package includes an instruction manual and warranty card alongside the meter.

Features and Construction

UT383 mini digital lux meter with backlight, 0–200,000 lux range and 163 × 55 mm body

The specification concentrates on illuminance measurement, reading retention and operating limits. These details make it possible to assess the UT383 by its stated range, controls and size without assuming an accuracy grade or construction material that has not been provided.

Material and Build

The meter has stated external dimensions of 163 × 55 mm, although its depth and enclosure materials are not listed. An overload is shown as OL, and the backlight assists display viewing. Current consumption is specified as no more than 30 mA during operation and no more than 10 μA when shut down. The battery supply is rated at 4.5V, but the required cell type and whether batteries are included are not stated.

Size and Practical Fit

At 163 × 55 mm, the UT383 has a clearly defined two-dimensional footprint for buyers comparing meter sizes. Its operating environment is 0–40°C with relative humidity no higher than 80% RH. For storage, the stated limits are -20–60°C and no higher than 75% RH. These figures describe the permitted environmental conditions rather than a waterproof or weather-resistance rating, which is not supplied.

Uses and Placement

UT383 mini digital lux meter with backlight, 0–200,000 lux range and 163 × 55 mm body

The meter can be used wherever a numerical illuminance reading is needed within its stated lux or foot-candle ranges. The measurement functions support general light checks, but no specialist calibration certificate, accuracy tolerance or industry compliance is claimed in the source information.

Event or Professional Use

For general workplace or event light checks, the 0.5-second sampling time provides regular reading updates as conditions change. MAX/MIN can record the highest and lowest values encountered during a measurement session, while HOLD keeps a selected reading on the display. The OL message identifies an overload rather than presenting an out-of-range value as a valid measurement. Users requiring certified measurements should note that no calibration or accuracy documentation is specified.

Everyday Home Use

Around the home, the UT383 can provide numerical light-level readings in rooms or other areas within its operating limits. The backlight assists when the display is difficult to see, and HOLD avoids relying on a reading that disappears as the meter is moved. Automatic shutdown after five minutes is a stated operating feature. The supplied instruction manual should be consulted for control operation, battery installation and any further usage guidance.

Benefits and Buying Value

UT383 mini digital lux meter with backlight, 0–200,000 lux range and 163 × 55 mm body

The buying value lies in the combination of a broad stated measuring range, reading-management controls and defined operating limits. The listed functions are directly relevant to comparing illuminance meters without relying on unsupported claims about precision, longevity or battery life.

Reuse and Low Maintenance

As a battery-powered measuring instrument, the UT383 can be used for repeated light checks within its specified environmental conditions. Automatic shutdown and the 3.0–3.5V low-battery prompt provide clear information about shutdown behaviour and battery status. No routine maintenance schedule is supplied, so care should remain limited to following the manual and observing the working and storage temperature and humidity limits.

Why Choose This Product

The UT383 combines 0–200,000 lux measurement, a 0–9,999 Fc range, 0.5-second sampling, MAX/MIN, HOLD, overload indication and a backlight in a 163 × 55 mm meter. Its five-minute automatic shutdown and stated current consumption add useful specification detail. The package includes the illuminance meter, instruction manual and warranty card. Buyers should note that accuracy, depth, enclosure materials and battery cell requirements are not provided.